©Endress+Hauser
©Endress+Hauser
Področje uporabe
CYK10 guarantees absolute water-proof connection of Memosens sensors to the transmitter. Its inductive coupling shows no contact corrosion and guarantees galvanic isolation of transmitter and medium. Simply forget about limited cable length, interfering potentials or moisture and benefit from completely safe and reliable signal transmission.
The Memosens data cable CYK10 is applied in Memosens systems measuring the following parameters:
Prednosti
Maximum process safety through non-contact, inductive and digital signal transmission: No contact corrosion, absolutely watertight, no interference potential.
Increased availability of the measuring point: Digital data transmission provides an automatic error message if the signal is lost.
More flexibility in plant planning and installation: Cable length up to 100 m is possible.
Approved for hazardous area use.
Get this product as part of a bundle
Enostavni produkti
Lahka izbira, vgradnja in uporaba
Tehnična odličnost
Preprostost
Standardni produkti
Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
Vrhunski produkti
Visoko funkcionalni in praktični
Tehnična odličnost
Preprostost
Specialni produkti
Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
FLEX izbira
Tehnična odličnost
Preprostost
Segment Fundamental
Zadostite svojim osnovnim merilnim potrebam
Tehnična odličnost
Preprostost
Segment Lean
Obvladajte ključne procese na preprost način
Tehnična odličnost
Preprostost
Segment Extended
Optimirajte procese z inovativnimi tehnologijami
Tehnična odličnost
Preprostost
Segment Xpert
Imejte pod nadzorom najzahtevnejše aplikacije
Tehnična odličnost
Preprostost
Zgodbe o uspehu
An automated system for pH measurements at AVR
AVR Waste in Botlek, Rotterdam, processes up to 1.7 million tons of residual waste per year. Discover how they optimized their pH measurement thanks to Endress+Hauser
Preberi celotno zgodbo
Pure high quality beer and clean wastewater
Discover how Heineken meets all regulations to protect the brazilian environment with the Viomax CAS51D digital nitrate or SAC sensor from Endress+Hauser.
Preberi celotno zgodbo
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Measuring range
High impedance cable not necessary
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Process pressure
max. 50 bar/725 psi at 135°C/275°F.
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals.
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter.
Characteristic
Inductive, digital transmission of measurement signals and energy. Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Merilni princip
Amperometric oxygen measurement
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Installation
Inductive plug- head for digital sensors with Memosens technology and wire terminals or M12 plug to connect to the transmitter
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 ... 135 °C (-13 ... 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Ex certification
ATEX II 1G Ex ia IIC T3/T4/T6 FM, CSA IS Cl.1 Div 1 Gr. A-D ATEX, NEPSI II 3G Ex nL IIC TIIS
Additional certifications
Also available as TÜV approved SIL version
Application
Measuring cable for contactless, inductive, digital transmission of measurement signals
Characteristic
Inductive, digital transmission of measurement signals and energy Not influenced by moisture, EMC-fields and corrosion
Design
Easy to handle Bajonett coupling to connect digital sensors with Memosens technology and plug-head No open contacts, resistant against humidity
Material
Cable sheath: TPE Junction box: aluminum
Dimension
Diameter: 6.3 mm (0.25 inch) Cores: 2x2 cores, twisted pairs Length: up to approx. 100 m (328 ft)
Process temperature
-25 to 135 °C (-13 to 277 °F)
Temperature sensor
For digital sensors with inductive plug-head with and without temperature sensor
Additional certifications
Also available as TÜV approved SIL version
Največkrat preneseno
Technical Information
Memosens measuring cable and installation
accessories
Angleška različica - 12/2011
CYK10 / CYK11
EN
SL
CS DE ES FR IT NL PL RU
01/12/2011
01/11/2001
Jezik:
angleščina
Verzija:
01/12/2011
Velikost datoteke:
718.3 KB
Ime datoteke:
TI00118CEN_1311.pdf
Dokumenti 53
Technical Information
Memosens measuring cable and installation
accessories
CYK10 / CYK11
EN
SL
češčina nemščina španščina French italijanščina nizozemščina poljščina ruščina
01/12/2011
01/11/2001
Jezik:
angleščina
Verzija:
01/12/2011
Velikost datoteke:
718.3 KB
Ime datoteke:
TI00118CEN_1311.pdf
CYK10, CYK11
Technical Information
Memosens measurement cables
EN
SL
nemščina French ruščina
01/12/2011
Jezik:
angleščina
Verzija:
01/12/2011
Velikost datoteke:
718.3 KB
Ime datoteke:
TI01477C_TI00118CEN_1311.pdf
Podatkovni kabel Memosens
EN
SL
bolgarščina češčina danščina nemščina grščina španščina estonščina finščina French hrvaščina madžarščina indonezijščina italijanščina japonščina korejščina Lithuanian Latvian nizozemščina norveščina poljščina portugalščina romunščina ruščina slovaščina švedščina tajščina turščina kitajščina
08/12/2021
28/02/2018
06/07/2016
28/08/2012
01/11/2011
Jezik:
slovenščina
Verzija:
08/12/2021
Velikost datoteke:
658.1 KB
Ime datoteke:
BA00118CSL_0520-00.pdf
XA Memosens data cable CYK10
Safety instructions for electrical apparatus in explosion-hazardous areas
EN
SL
portugalščina
23/09/2024
Jezik:
angleščina
Verzija:
23/09/2024
Velikost datoteke:
513 KB
Ime datoteke:
XA03307CEN_0124-00.pdf
FM IS Cl. I Div. I Gr. A, B, C and D Safety instructions for electrical apparatus in explosion-hazardous areas
Jezik:
angleščina
Verzija:
15/03/2022
Velikost datoteke:
503.5 KB
Ime datoteke:
XA02846CEN_0122-00.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
SL
nemščina French
11/11/2016
31/12/2011
01/04/2009
Jezik:
angleščina
Verzija:
11/11/2016
Velikost datoteke:
3.7 MB
Ime datoteke:
XA00079CA3_1416.pdf
Memosens data cable CYK10
Safety instructions for electrical apparatus inexplosion-hazardous areas UK Ex II 1 G Ex ia IIC T3/T4/T6 Ga
Jezik:
angleščina
Verzija:
08/12/2021
Velikost datoteke:
499.6 KB
Ime datoteke:
XA02783CEN_0121-00.pdf
Memosens data cable Safety instructions for electrical apparatus in explosion-hazardous areas
EN
SL
kitajščina
12/11/2024
29/03/2022
Jezik:
angleščina
Verzija:
12/11/2024
Velikost datoteke:
602.5 KB
Ime datoteke:
XA02845CEN_0224-00.pdf
Memosens pH/ORP
Sicherheitshinweise für elektrische Betriebsmittel im
explosionsgefährdeten Bereich
Safetyinstructions for electrical apparatus for explosion-hazardous
areas
Conseils de sécurité pour matériels électriques destinés aux zones
explosibles
Safety Instructions
Safety instructions for electrical apparatus for explosion-hazardous areas
EN
SL
nemščina French poljščina
22/02/2016
04/03/2015
14/01/2013
21/10/2010
01/12/2006
Jezik:
angleščina
Verzija:
22/02/2016
Velikost datoteke:
4.3 MB
Ime datoteke:
XA00376CA3_1616.pdf
Merilni kabel CYK10 Dodatek k dokumentu BA00118C Varnostna navodila za električno opremo v nevarnih območjih ATEX II 1G Ex ia IIC T3/T4/T6 Ga IECEx Ex ia IIC T3/T4/T6 Ga
EN
SL
bolgarščina češčina danščina nemščina grščina španščina estonščina finščina French hrvaščina madžarščina italijanščina Lithuanian Latvian nizozemščina poljščina portugalščina romunščina slovaščina švedščina
14/12/2021
Jezik:
slovenščina
Verzija:
14/12/2021
Velikost datoteke:
513.5 KB
Ime datoteke:
XA02800CSL_0121-00.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
No spare parts available.
Cenimo vašo zasebnost
Uporabljamo piškotke, da bi lahko izboljšali vašo izkušnjo med brskanjem, zbirali statistične podatke za izboljšanje delovanja spletnega mesta in zagotavljali prilagojene oglase ali vsebine.
Z izbiro "Sprejmi vse" se strinjate z našo uporabo piškotkov.
Za podrobnosti si oglejte naš Pravilnik o piškotkih .
Prilagodi
Sprejmi samo bistveno
Sprejmi vse