Lastnosti na dlani
-
Process temperature
–50°C...+150°C
(–58°F...+300°F) -
Process pressure / max. overpressure limit
Vacuum...40 bar
(580 psi) -
Min. density of medium
Density from 0.4 g/cm3
(0.4 SGU)
Področje uporabe
Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill protection in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for liquids up to SIL3.
Process connections: Threads and flanges
Temperature: -50 to +150°C (-76 to +300°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Sensor length: Extension pipe up to 3m (9.8ft)
Sensor material: Enamel, ECTFE and various PFA materials
International explosion protection certificates, overfill protection WHG, SIL
Prednosti
Use in safety systems requiring functional safety to SIL3 in accordance with IEC 61508 Ed.2.0/ IEC 61511-1/ISA 84-1 and DIN EN ISO 13849
Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button
Permanent self-monitoring/internal redundancy
4-20mA interface (acc. to NAMUR NE 06/NE 43): easy integration via the switching unit (Nivotester FailSafe FTL825) with a two-channel output (safety contacts) and locking function or direct integration into a safety PLC
No adjustment: quick, low-cost startup
No mechanically moving parts: no maintenance, no wear, long operating life
Monitoring of fork for damage, corrosion, buildup and mechanical blocking
Videoposnetki
Segment Xpert
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
-
Standardni produkti
- Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
FLEX izbira | Tehnična odličnost | Preprostost |
---|---|---|
Segment Fundamental Zadostite svojim osnovnim merilnim potrebam |
Tehnična odličnost
|
Preprostost
|
Segment Lean Obvladajte ključne procese na preprost način |
Tehnična odličnost
|
Preprostost
|
Segment Extended Optimirajte procese z inovativnimi tehnologijami |
Tehnična odličnost
|
Preprostost
|
Segment Xpert Imejte pod nadzorom najzahtevnejše aplikacije |
Tehnična odličnost
|
Preprostost
Spremenljivo |
-
-
Tehnične informacije (TI)
Liquiphant FailSafe FTL80, FTL81, FTL85 Technical Information
Vibronic
Point level switch for liquidsEN SL 04/06/201316/07/2012Jezik:
angleščina
Verzija:
04/06/2013
Velikost datoteke:
678.4 KB
Ime datoteke:
TI01026FEN_0213.pdf
-
-
-
Navodila za uporabo (BA)
Liquiphant FailSafe FTL80, FTL81, FTL85 Operating Instructions
Vibronic
Point level switch for liquidsEN SL 04/06/201316/07/2012Jezik:
angleščina
Verzija:
04/06/2013
Velikost datoteke:
768.4 KB
Ime datoteke:
BA01037FEN_0213.pdf
-
-
-
Navodila za vgradnjo (EA)
Graphite gaskets Installation instruction
Liquiphant M, LIquiphant S, Liquiphant FailSafe
EN SL 11/04/2012Jezik:
angleščina
Verzija:
11/04/2012
Velikost datoteke:
363.6 KB
Ime datoteke:
EA0008FA2_0708.pdf
-
-
-
Navodila za vgradnjo (EA)
Electronics on Liquiphant M/S/FailSafe Installation instruction
Liquiphant M/S/FailSafe
EN SL 09/07/2012Jezik:
angleščina
Verzija:
09/07/2012
Velikost datoteke:
359 KB
Ime datoteke:
EA01030FA2_0112.pdf
-
-
-
Navodila za vgradnjo (EA)
Cover for housing T13 electronic compartment with sight glas Installation instruction
Liquicap M, Solicap M, Liquphant M/S/FailSafe, Soliphant M
EN SL 09/08/2012Jezik:
angleščina
Verzija:
09/08/2012
Velikost datoteke:
158.7 KB
Ime datoteke:
EA01049FA2_01.12.pdf
-
-
-
Navodila za vgradnjo (EA)
Cover for housing T13 electronic compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN SL 11/08/201409/08/2012Jezik:
angleščina
Verzija:
11/08/2014
Velikost datoteke:
164.3 KB
Ime datoteke:
EA01048FA2_0214.pdf
-
-
-
Navodila za vgradnjo (EA)
Cover for housing F27 Installation instruction
Liquihant M/S, Soliphant M, Liquicap M, Solicap M/S
EN SL 11/08/201416/01/201409/08/2012Jezik:
angleščina
Verzija:
11/08/2014
Velikost datoteke:
136.4 KB
Ime datoteke:
EA01047FA2_0314.pdf
-
-
-
Navodila za vgradnjo (EA)
Cover for housing F13 Installation instruction
Liquiphant M/S, SoliphantM, Liquicap M, Solicap M/S
EN SL 11/08/201409/08/2012Jezik:
angleščina
Verzija:
11/08/2014
Velikost datoteke:
134.4 KB
Ime datoteke:
EA01046FA2_0214.pdf
-
-
-
Navodila za vgradnjo (EA)
Diagnostics plug Installation instruction
Liquiphant M/S/FailSafe, Soliphant T/M
EN SL 24/04/201511/10/2012Jezik:
angleščina
Verzija:
24/04/2015
Velikost datoteke:
71.5 KB
Ime datoteke:
EA01063FA2_0215.pdf
-
-
-
Navodila za vgradnjo (EA)
Cover for housing T13 terminal compartment Installation instruction
Liquiphant M/S, Soliphant M, Liquicap M, Solicap M/S
EN SL 24/02/202215/08/201409/08/2012Jezik:
angleščina
Verzija:
24/02/2022
Velikost datoteke:
119 KB
Ime datoteke:
EA01050FA2_0322.pdf
-