Accuracy
Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):
+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):
+/- 10 mm (0.39 in) -
Process temperature
-50...+200 °C
(-58...+392 °F) -
Process pressure / max. overpressure limit
Vacuum...40 bar
(Vacuum...580 psi) -
Max. measurement distance
Rod:
4 m (13 ft) Min DK>1.6
Rope:
25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK>1,9 -
Main wetted parts
Rod probe:
304, 304L, 316L, PTFE, PFA
Rope probe:
304, 304L, 316, 316L, PTFE, PFA
Področje uporabe
Levelflex FMP52 for level measurement in aggressive liquids with chemically resistant gap-free PFA-coated probe. All wetted parts are FDA listed materials. FMP52 guided radar offers maximum reliability even in case of moved surface. Levelflex FMP52 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod or rope probe.
Process connections: Flange or process connections for hygiene requirements (Tri-Clamp, 11851)
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 4m (13ft), rope 45m (148ft)
Accuracy: Rod probe ±2mm (0.08")
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval, 5-point linearity protocol
Prednosti
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
World's easiest proof test for SIL and WHG saves time and costs
Videoposnetki
Segment Extended
-
Vrhunski produkti
- Visoko funkcionalni in praktični
Tehnična odličnost
Preprostost
-
Standardni produkti
- Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
FLEX izbira | Tehnična odličnost | Preprostost |
---|---|---|
Segment Fundamental Zadostite svojim osnovnim merilnim potrebam |
Tehnična odličnost
|
Preprostost
|
Segment Lean Obvladajte ključne procese na preprost način |
Tehnična odličnost
|
Preprostost
|
Segment Extended Optimirajte procese z inovativnimi tehnologijami |
Tehnična odličnost
|
Preprostost
|
Segment Xpert Imejte pod nadzorom najzahtevnejše aplikacije |
Tehnična odličnost
|
Preprostost
Spremenljivo |
Predhodnik
-
-
Tehnične informacije (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN SL 25/03/202415/09/202328/10/202130/07/202119/06/2020Jezik:
angleščina
Verzija:
25/03/2024
Velikost datoteke:
1.1 MB
Ime datoteke:
TI00426FEN_2524.pdf
-
-
-
Tehnične informacije (TI)
TI Levelflex FMP51, FMP52, FMP54
Guided-wave radar
EN SL 01/10/202422/02/202312/04/202231/07/202004/03/2019Jezik:
angleščina
Verzija:
01/10/2024
Velikost datoteke:
5 MB
Ime datoteke:
TI01001FEN_3024-00.pdf
-
-
-
Navodila za uporabo (BA)
Levelflex / Levelflex M Zentrierscheibe / Centering disk (PFA) Mounting Instructions
Accessory
EN SL 29/09/201727/02/201425/04/201208/02/201124/09/2010Jezik:
angleščina
Verzija:
29/09/2017
Velikost datoteke:
82.6 KB
Ime datoteke:
BA00378FA2_1717.pdf
-
-
-
Navodila za uporabo (BA)
BA Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
Guided-wave radar
EN SL 01/10/202421/02/202330/06/202212/04/201816/11/2017Jezik:
angleščina
Verzija:
01/10/2024
Velikost datoteke:
4.9 MB
Ime datoteke:
BA01006FEN_2124-00.pdf
-
-
-
Navodila za uporabo (BA)
BA Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Guided-wave radar
EN SL 01/10/202421/02/202330/06/202212/04/201816/11/2017Jezik:
angleščina
Verzija:
01/10/2024
Velikost datoteke:
6.1 MB
Ime datoteke:
BA01052FEN_0924-00.pdf
-
-
-
Navodila za uporabo (BA)
BA Levelflex FMP51, FMP52, FMP54 HART
Guided-wave radar
EN SL 01/10/202413/12/202230/06/202231/07/202012/04/2018Jezik:
angleščina
Verzija:
01/10/2024
Velikost datoteke:
5.4 MB
Ime datoteke:
BA01001FEN_2524-00.pdf
-
-
-
Parametri naprave (GP)
Levelflex FMP5x HART Description of Device Parameters
Guided wave radar
EN SL 28/04/201630/10/201426/02/201429/07/201101/10/2010Jezik:
angleščina
Verzija:
28/04/2016
Velikost datoteke:
3.3 MB
Ime datoteke:
GP01000FEN_1616.pdf
-
-
-
Parametri naprave (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 PROFIBUS PA Description of Device Parameters
Guided wave radar
EN SL 30/10/201404/08/2011Jezik:
angleščina
Verzija:
30/10/2014
Velikost datoteke:
4.7 MB
Ime datoteke:
GP01001FEN_1314.pdf
-
-
-
Parametri naprave (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 FOUNDATION Fieldbus Description of Device Parameters
Guided wave radar
EN SL 09/06/201527/04/2012Jezik:
angleščina
Verzija:
09/06/2015
Velikost datoteke:
3.5 MB
Ime datoteke:
GP01015FEN_0215.pdf
-
-
-
Kratka navodila (KA)
Levelflex FMP51, FMP52, FMP54 HART
Vodeni radar
EN SL 30/06/202205/04/202212/04/201817/11/201712/02/2015Jezik:
slovenščina
Verzija:
05/04/2022
Velikost datoteke:
1.5 MB
Ime datoteke:
KA01077FSL_1922-00.pdf
-