Lastnosti na dlani
-
Accuracy
Standard 0.2%
Optional 0.1% -
Process temperature
PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F -
Pressure measuring range
100mbar...10bar
(1.5psi...150psi) -
Process pressure / max. overpressure limit
40 bar (600 psi)
-
Main wetted parts
Alloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh -
Max. measurement distance
100 m (328 ft) H2O
-
Material process membrane
316L, AlloyC,
Gold-Rhodium
PE, FEP -
Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
Področje uporabe
The Deltapilot FMB53 is a cable version with mounting clamp. This device with the Contite measuring cell is typically used in the environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.
For level measurement.
Process connection: Suspension clamp
Temperature: With PE cable: -10 to +70°C (+14 to +158°F),
with FEP cable: -10 to +80°C (+14 to +176°F)
Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)
Accuracy: ±0.2%, ±0.1% (option)
International explosion protection certificates, overfill prevention WHG, SIL, drinking water approval
Prednosti
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
Modular concept for easy replacement of display or electronics
Seamless and independent system integration (HART/PA/FF)
Easy and safe menu-guided operation: On-site via display module, via 4 to 20mA with HART, via PROFIBUS PA, via FOUNDATION Fieldbus
International usage thanks to a wide range of approvals
Videoposnetki
Segment Lean
-
Standardni produkti
- Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
-
Standardni produkti
- Zanesljivi, robustni, nezahtevni za vzdrževanje
Tehnična odličnost
Preprostost
-
Specialni produkti
- Zasnovani za posebej zahtevne aplikacije
Tehnična odličnost
Preprostost
Spremenljivo
FLEX izbira | Tehnična odličnost | Preprostost |
---|---|---|
Segment Fundamental Zadostite svojim osnovnim merilnim potrebam |
Tehnična odličnost
|
Preprostost
|
Segment Lean Obvladajte ključne procese na preprost način |
Tehnična odličnost
|
Preprostost
|
Segment Extended Optimirajte procese z inovativnimi tehnologijami |
Tehnična odličnost
|
Preprostost
|
Segment Xpert Imejte pod nadzorom najzahtevnejše aplikacije |
Tehnična odličnost
|
Preprostost
Spremenljivo |
Predhodnik
-
-
Tehnične informacije (TI)
TI Deltapilot M FMB50, FMB51, FMB52, FMB53
Angleška različica - 04/2024
Hydrostatic level measurement IO-Link, HART, PA, FF
EN SL 01/04/202422/08/202201/07/202113/07/201610/12/2014Jezik:
angleščina
Verzija:
01/04/2024
Velikost datoteke:
2.7 MB
Ime datoteke:
TI00437PEN_2424-00.pdf
-
-
-
Tehnične informacije (TI)
TI Deltapilot M FMB50, FMB51, FMB52, FMB53
Hydrostatic level measurement
IO-Link, HART, PA, FFEN SL 01/04/202422/08/202201/07/202113/07/201610/12/2014Jezik:
angleščina
Verzija:
01/04/2024
Velikost datoteke:
2.7 MB
Ime datoteke:
TI00437PEN_2424-00.pdf
-
-
-
Navodila za uporabo (BA)
Cerabar M /Deltabar M /Deltapilot M Operating Instructions PROFIBUS PA
Cerabar M PMC51, PMP51, PMP55, Pressure transmitter
Deltabar M
PMD55 Differential pressure transmitter Deltapilot M FMEN SL 13/07/201610/12/201411/06/201417/08/201225/01/2012Jezik:
angleščina
Verzija:
13/07/2016
Velikost datoteke:
7.8 MB
Ime datoteke:
BA00383PEN_0816.pdf
-
-
-
Navodila za uporabo (BA)
Cerabar M, Deltabar M, Deltapilot M HART (V 01.00.zz)
Cerabar M PMC51, PMP51/55 Pressure transmitter
Deltabar M
PMD55
Differential pressure transmitter
Deltapilot M FMB50/5EN SL 13/07/201610/12/201411/06/201417/08/201225/01/2012Jezik:
angleščina
Verzija:
13/07/2016
Velikost datoteke:
4.8 MB
Ime datoteke:
BA00382PEN_2016.pdf
-
-
-
Navodila za uporabo (BA)
Cerabar M / Deltabar M / Deltapilot M, Operating Instructions FOUNDATION Fieldbus
Cerabar M PMC51, PMP51, PMP55 Pressure transmitter
Deltabar M PMD55 Differential pressure transmitter
Deltapilot M FMB50 Hydrostatic pressure transmitterEN SL 13/07/201610/12/201411/06/201417/08/201225/01/2012Jezik:
angleščina
Verzija:
13/07/2016
Velikost datoteke:
7.8 MB
Ime datoteke:
BA00384PEN_0816.pdf
-
-
-
Kratka navodila (KA)
Deltapilot M FMB50, FMB51, FMB52, FMB53
Hidrostatično merjenje nivoja
HARTEN SL 15/12/202113/07/201610/12/201411/06/201425/01/2012Jezik:
slovenščina
Verzija:
15/12/2021
Velikost datoteke:
987.3 KB
Ime datoteke:
KA01033PSL_1821-00.pdf
-
-
-
Kratka navodila (KA)
Deltapilot M FMB50, FMB51, FMB52, FMB53
Hidrostatično merjenje nivoja
PROFIBUS PAEN SL 30/09/202113/07/201610/12/201411/06/201425/01/2012Jezik:
slovenščina
Verzija:
30/09/2021
Velikost datoteke:
961 KB
Ime datoteke:
KA01034PSL_0621-00.pdf
-
-
-
Kratka navodila (KA)
Deltapilot M FMB50, FMB51, FMB52, FMB53
Hidrostatično merjenje nivoja
FOUNDATION FieldbusEN SL 30/09/202113/07/201610/12/201411/06/201425/01/2012Jezik:
slovenščina
Verzija:
30/09/2021
Velikost datoteke:
932.1 KB
Ime datoteke:
KA01035PSL_0621-00.pdf
-
-
-
Navodila za vgradnjo (EA)
Housing filters
Gammapilot, Micropilot, Liquiphant
Cerabar, DeltabarEN SL 21/02/202331/07/2020Jezik:
angleščina
Verzija:
21/02/2023
Velikost datoteke:
435.7 KB
Ime datoteke:
EA01312PEN_0223-00.pdf
-
-
-
Navodila za vgradnjo (EA)
Installation instruction - Ground terminal T14/T15/T17, F30/F31
Cerabar S, Deltabar S, Deltabar, Cerabar M, Deltabar M, Deltapilot M
EN SL 22/06/2015Jezik:
angleščina
Verzija:
22/06/2015
Velikost datoteke:
282.8 KB
Ime datoteke:
EA01131PA2_0115.pdf
-
-
-
Navodila za vgradnjo (EA)
Measuring cell Installation instruction
Deltapilot M FMB51, FMB52, FMB53
EN SL 12/04/2012Jezik:
angleščina
Verzija:
12/04/2012
Velikost datoteke:
348.7 KB
Ime datoteke:
EA0027PA2_0410.pdf
-